Modular Clean Room Specification Mobile Clean Room Customized Customized Size

1 Set
MOQ
Modular Clean Room Specification Mobile Clean Room Customized Customized Size
Caratteristiche Galleria Descrizione di prodotto Richieda una citazione
Caratteristiche
Specificazioni
Model Number: Clean Booth
After-sales Service Provided: Engineers available to service machinery overseas
Frame: Stainless Steel
Construction: Acrylic Glass or PVC
Certificazione: ISO9001:2008
Type: Hardwall or Softwall
Cleanliness:: ISO 5
Size:: Customized Size
Voltage:: IP 220V or 3P 380V
Optional:: Pass box
Keyword:: Modular Clean Room
Product Name:: Customized Modular Clean Room Specification Mobile Clean Room
Informazioni di base
Certificazione: ISO9001:2008
Model Number: Clean Booth
Termini di pagamento e spedizione
Packaging Details: Standard export packing (Bubble+foam+Carton+Plywood case) or as client required Customized Modular Clean Room Specification Mobile Clean Room
Supply Ability: 150 Set/Sets per Month
Descrizione di prodotto

Customized Modular Clean Room Specification Mobile Clean Room

 

I. MODULAR CLEANROOMS: Exceptional Yet Economical Solutions

Customized Modular Clean Room Specification Mobile Clean Room provides a kind of air cleaning environment in which dust free production, assembly, preparation and packing can be guaranteed. It is the easiest, fatest yet the most convenient and economical way to build a clean room instead of a clean room engineering. Modular clean room can be customized and can be equipped with different optional equipment according to the working progress. Compared to clean roomengineering, modular clean room boasts shorter construction time and is flexible and movable. In addition, Customized Modular Clean Room Specification Mobile Clean Room is easy and convenient for installation and also easy for operation by self-developed control panel. It also can be installed in part of clean room of general class which requires high cleanliness to save cost. Customized Modular Clean Room Specification Mobile Clean Room has following advantages:

 

· Lower manufacturing and installation costs by not designing the whole cleanroom while can meet the highest level of clean class required

· Customized design is welcomed.

· It can be used singly or combined from small area of 4 square meters to 200 square meters.

· Bi-swing interlocking door with self-closing hinges to avoid cross contamination and maintain room pressure

· HEPA Fan Filter Units (FFUs) ensure ISO 5 to ISO 9 clean class environment.

· Modular construction, easy to increase clean class, good expansion and reusable, convenient movement

 

II. TYPE OF CLEAN ROOM

 

1. Softwall Clean Room

Softwall Clean Rooms boasts the most economical modular cleanroom wall construction, which is comprised of transparent and flexible PVC panels placed onto a solid stainless steel frame. These PVC panels enclose the clean area thus preventing dusts from outside. These PVC panels usually overlap, ensuring that walls of the softwall modular clean room are efficient shield which is solid and endurable, when in position. PVC panels also can avoid particles to enter the room and some have anti static functions. In softwall modular clean rooms, positive airflow filtered by FFUs pushes air down through the cleanroom, allowing particles to be flushed out through the outlet at the bottom of the room.

 

2. Hardwall Clean Room

 

Hardwall modular clean rooms have a high-integrity wall construction. acrylic and sandwich panels are mounted within robust steel frames to create un-breachable walls which enclose the clean area. The acrylic allows full visibility for supervisors to monitor the working environment and also the workers. The whole structure is free standing and no suspended ceiling is need thus reducing the installation costs and making it more convenient to install and operate. 

 

 

  II. FIELD OF APPLICATION

 

Bio-pharmaceuticals, medical treatment, food, LCM, camera module, touch screen, optical module, FILM, and other production or experimental environment;

 

IV.  STRUCTURE

CONFIGURATION

Control Panel

Self-developed integrated control panel designed and installed to adjust relevant parameters such as air velocity, pressure, etc. and also control the modular clean room

Ceiling Cover

The ceiling is covered by FFUs and blind plates which can protect ceiling light modules and also solid enough for HEPA filter replacement.

Acrylic Wall

Offer full visibility for monitoring and outstanding tensile strength. These economical panels are lightweight and easy to clean.

Pass Box

An optional device for transferring objects in or out of clean room so as to avoid cross contamination. Pass boxes have two electronic interlocking doors maxmize the efforts of maintaining cleanliness

FFU

The core of modular clean room which filter the fresh air from clean air into the clean room so as to maintain clean area from ISO 5 to ISO 9

Pressure Damper

Improve safety and lessens repairs costs by withstanding wind gusts and also maintaining stable pressure

 

V.  SPECIFICATIONS

 

Other Optional Equipment

 

 